• head_banner_01

Suiga Hirschmann DRAGON MACH4000-52G-L3A-MR

Fa'amatalaga Pupuu:

Suiga atoa o le Gigabit Ethernet Backbone ma uafu GE e oo atu i le 48x + 4x 2.5/10, mamanu modular, ua fa'apipi'i le iunite ili, ua aofia ai paneta tauaso mo laina kata ma avanoa o le sapalai eletise, foliga fa'apitoa o le Layer 3 HiOS, fa'asologa o feso'ota'iga tele.


Fa'amatalaga o le oloa

Fa'ailoga o Oloa

Aso Fa'apisinisi

 

Oloafa'amatalaga

Ituaiga: DRAGON MACH4000-52G-L3A-MR
Igoa: DRAGON MACH4000-52G-L3A-MR
Fa'amatalaga: O le Full Gigabit Ethernet Backbone Switch e oʻo atu i le 52x GE ports, mamanu modular, ua faʻapipiʻiina le ili, ua aofia ai paneli tauaso mo le laina kata ma avanoa o le sapalai eletise, foliga faʻapitoa o le Layer 3 HiOS, multicast routing
Lomiga o le Polokalama Faakomepiuta: HiOS 09.0.06
Numera o le Vaega: 942318003
Ituaiga o le uafu ma le aofaʻi: O le aofaʻi o uafu e oʻo atu i le 52, Iunite autū 4 uafu tumau: 4x GE SFP, Modular: 48x FE/GE uafu e mafai ona faʻalauteleina ma avanoa e fa mo le module o ala o faasalalauga, 12x FE/GE uafu i le module taʻitasi

 

Fa'amatalaga atili Feso'ota'iga

V.24 feso'ota'iga: 1 x soketi RJ45
Pusa mo le kata SD: 1 x e fa'afeso'ota'i ai le adapter fa'atulagaina otometi ACA31 (SD)
Feso'ota'iga USB: 1 x USB e fa'afeso'ota'i ai le adapter fa'atulagaina otometi ACA22-USB

 

Malosiagamana'oga

Voltage Fa'agaoioia:

Fa'aulufalega o le iunite PSU: 100 - 240 V AC; e mafai ona fa'agaoioia le ki i le 1 pe 2 iunite PSU e mafai ona suia i le fanua (e mafai ona fa'atonuina eseese)

Fa'aaogaina o le eletise:

80 W (e aofia ai masini fa'asalalau SFP + 1 PSU + Fan module)

 

Polokalama Faakomepiuta

  

Fesuiaiga:

Aoaoina Tutoatasi o le VLAN, Vave ona Matua, Fa'amaumauga o Tuatusi Unicast/Multicast Tumau, Fa'amuamua o le QoS / Port (802.1D/p), Fa'amuamua o le TOS/DSCP, Faiga Fa'atuatuaina o le Interface, Pulega o le Queue CoS, Fa'avasegaga ma le Puipuiga o le IP Ingress DiffServ, Fa'avasegaga ma le Puipuiga o le IP Egress DiffServ, Fa'atulagaina o le Queue / Max. Queue Bandwidth, Pulea o le Tafe (802.3X), Fa'atulagaina o le Interface Egress, Puipuiga o le Afa Ingress, Jumbo Frames, VLAN (802.1Q), VLAN fa'avae i luga o le Protocol, VLAN Unaware Mode, GARP VLAN Registration Protocol (GVRP), Voice VLAN, MAC-based VLAN, IP subnet-based VLAN, GARP Multicast Registration Protocol (GMRP), IGMP Snooping/Querier i le VLAN (v1/v2/v3), Fa'amama Multicast e Le'o Iloa, Multiple VLAN Registration Protocol (MVRP), Multiple MAC Registration Protocol (MMRP), Multiple Registration Protocol (MRP), Layer 2 Loop Protection
Fa'aopoopoina: HIPER-Ring (Ring Switch), HIPER-Ring over Link Aggregation, Link Aggregation ma le LACP, Link Backup, Media Redundancy Protocol (MRP) (IEC62439-2), MRP over Link Aggregation, Redundant Network Coupling, Sub Ring Manager, RSTP 802.1D-2004 (IEC62439-1), MSTP (802.1Q), RSTP Guards, VRRP, VRRP Tracking, HiVRRP (fa'aleleia atili o le VRRP)
Pulega: Lagolagoina o Ata o Polokalama Fa'alua, TFTP, SFTP, SCP, LLDP (802.1AB), LLDP-MED, SSHv2, V.24, HTTP, HTTPS, Traps, SNMP v1/v2/v3, Telnet, DNS Client, OPC-UA Server
 Su'esu'ega: Iloa o Fete'ena'iga o Tuatusi Pulega, Fa'asilasilaga MAC, Feso'ota'iga Fa'ailo, Fa'ailoga o le Tulaga o le Masini, TCPDump, LEDs, Syslog, Fa'amaumauga Fa'aauau i le ACA, Fa'asilasilaga Imeli, Mata'ituina o le Uafu ma le Fa'agata Fa'a'ole'ole Otometi, Iloa o le Link Flap, Iloa o le So'ona Uta, Iloa o le Duplex Mismet, Saosaoa o le Feso'ota'iga ma le Mata'ituina o le Duplex, RMON (1,2,3,9), Port Mirroring 1:1, Port Mirroring 8:1, Port Mirroring N:1, RSPAN, SFLOW, VLAN Mirroring, Port Mirroring N:2, Fa'amatalaga o le Faiga, Su'ega-Ese'ese i le Cold Start, Su'ega o le Uaea Kopa, Pulega o le SFP, Talanoaga Siaki Fa'atulagaina, Switch Dump, Ata Fa'atulagaina o le Ata
 Fa'atulagaga: Toe Fa'afo'isia o le Fa'atulagaga Otometi (toe fa'afo'i), Fa'atulagaga o Tama'ilima, Faila Fa'atulagaina e Fa'avae i Tusitusiga (XML), BOOTP/DHCP Client ma le Fa'atulagaina Otometi, 'Au'aunaga DHCP: i le Port, 'Au'aunaga DHCP: Vaita'ele i le VLAN, Adapter Fa'atulagaina Otometi ACA31 (kata SD), Adapter Fa'atulagaina Otometi ACA21/22 (USB), HiDiscovery, DHCP Relay ma le Filifiliga 82, Fa'aoga o le Laina Poloaiga (CLI), Tusitusiga CLI, Lagolago MIB Fa'apitoa, Pulega Fa'avae i luga o le Upega Tafa'ilagi, Fesoasoani e Mafa'atatau i le Tulaga
  

Puipuiga:

Puipuiga o le Uafu e fa'avae i le MAC, Pulea o Avanoa e fa'avae i le Uafu ma le 802.1X, VLAN Malo/lē Fa'amaonia, 'Au'aunaga Fa'amaonia Tu'ufa'atasi (IAS), Tofiga o le VLAN RADIUS, Tofiga o le Faiga Fa'avae RADIUS, Fa'amaoniga o le Tele-Kamupani i le Uafu, Fa'a'ese'esega o le Fa'amaoniga MAC, DHCP Snooping, Leoleo Punaoa IP, Su'esu'ega ARP Fa'aolaola, Puipuiga o le Teena o Auaunaga, LDAP, Ingress MAC-based ACL, Egress MAC-based ACL, Ingress IPv4-based ACL, Egress IPv4-based ACL, Time-based ACL, VLAN-based ACL, Ingress VLAN-based ACL, Egress VLAN-based ACL, ACL Fa'atapula'aina o le Tafe, Avanoa i le Pulega e fa'atapula'aina e le VLAN, Fa'ailoga o le Puipuiga o le Masini, Su'esu'ega Ala, Fa'amaumauga CLI, Pulega o Tusi Fa'amaonia HTTPS, Avanoa Fa'atapula'aina o le Pulega, Fa'ailoga Fa'aoga Talafeagai, Faiga Fa'avae o Upu Fa'alilolilo e Mafai ona Fa'atulagaina, Numera o Taumafaiga Ulufale e Mafai ona Fa'atulagaina, Fa'amaumauga SNMP, Tele Tulaga Fa'apitoa, Pulega o Tagata Fa'aoga i le Lotoifale, Fa'amaoniga Mamao e ala i le RADIUS, Tagata Fa'aoga Loka o le Akauni, Suiga o le upu faataga i le taimi muamua e ulufale ai
Fa'asologa o taimi: Uati Manino PTPv2 e lua-laasaga, Uati Tuaoi PTPv2, Uati Taimi Moni Fa'amauina, SNTP Client, SNTP Server
Mea eseese: Sopoia o Uaea Fa'a-Tusi, Fa'aitiitia le Malosiaga o le Uafu

 

 

 Fa'asologa o ala:

Fesoasoani IP/UDP, Auala Fa'asolosolo Saosaoa Atoatoa, Feso'ota'iga Router e fa'avae i luga o le Uafu, Feso'ota'iga Router e fa'avae i luga o le VLAN, Feso'ota'iga Loopback, Fa'amama ICMP, Fa'asalalauga Fa'atonutonuina i luga o le Net, OSPFv2, RIP v1/v2, ICMP Router Discovery (IRDP), Tau Tutusa o Ala Tele (ECMP), Auala Fa'asolosolo Unicast, Proxy ARP, Siakiina o Auala Fa'asolosolo, IGMP v1/v2/v3, IGMP Proxy (Auala Fa'asolosolo Multicast), DVMRP, PIM-DM (RFC3973), PIM-SM / SSM (RFC4601)

Fa'asologa o le Multicast: DVMRP, PIM-DM (RFC3973), PIM-SM / SSM (RFC4601)

 

Siosiomagatulaga

Vevela o le fa'agaioiga: 0-+60 °C
Vevela o le teuina/felauaiga: -40-+70 °C
Susū fa'atatau (e le fa'aputu): 10-95%

 

Mekanika fausiaina

Fua (WxHxD): 480 mm x 88 mm x 445 mm
Fa'apipi'iina: 19" kapeneta pulea
Vasega puipuiga: IP20

 

 

Fa'asologa

Mea #

Ituaiga

942318002

DRAGON MACH4000-52G-L3A-UR

 

 

Fa'ata'ita'iga o lo'o maua i le Hirschmann DRAGON MACH4000 Series

DRAGON MACH4000-48G+4X-L2A

DRAGON MACH4000-48G+4X-L3A-UR

DRAGON MACH4000-48G+4X-L3A-MR

DRAGON MACH4000-52G-L2A

DRAGON MACH4000-52G-L3A-UR

DRAGON MACH4000-52G-L3A-MR


  • Muamua:
  • Sosoo ai:

  • Tusi lau savali iinei ma lafo mai ia i matou

    Oloa e feso'ota'i

    • Hirschmann MACH102-8TP-R Suiga

      Hirschmann MACH102-8TP-R Suiga

      Fa'amatalaga Pu'upu'u O le Hirschmann MACH102-8TP-R o le 26 port Fast Ethernet/Gigabit Ethernet Industrial Workgroup Switch (ua fa'apipi'iina le fa'aleleia: 2 x GE, 8 x FE; e ala i Media Modules 16 x FE), pulea, Software Layer 2 Professional, Store-and-Forward-Switching, fanless Design, redundant power supply. Fa'amatalaga Fa'amatalaga oloa Fa'amatalaga: 26 port Fast Ethernet/Gigabit Ethernet Industrial Workgroup Sw...

    • Ki o le Hirschmann RS20-1600M2M2SDAUHC/HH mo le Ethernet Alamanuia e le'i Puleaina

      Hirschmann RS20-1600M2M2SDAUHC/HH Kamupani e le'i pulea...

      Faatomuaga O suiga o le RS20/30 Unmanaged Ethernet Hirschmann RS20-1600M2M2SDAUHC/HH Fa'ata'ita'iga Fa'atulagaina RS20-0800T1T1SDAUHC/HH RS20-0800M2M2SDAUHC/HH RS20-0800S2S2SDAUHC/HH RS20-1600M2M2SDAUHC/HH RS20-1600S2S2SDAUHC/HH RS30-0802O6O6SDAUHC/HH RS30-1602O6O6SDAUHC/HH RS20-0800S2T1SDAUHC RS20-1600T1T1SDAUHC RS20-2400T1T1SDAUHC

    • Ki o le Hirschmann SPIDER II 8TX/2FX EEC Ethernet Alamanuia e le'i pulea

      Hirschmann SPIDER II 8TX/2FX EEC Kamupani e le'i pulea...

      Fa'amatalaga o le oloa Oloa: SPIDER II 8TX/2FX EEC Unmanaged 10-port Switch Fa'amatalaga o le oloa Fa'amatalaga: Entry Level Industrial ETHERNET Rail-Switch, store and forward switching mode, Ethernet (10 Mbit/s) ma le Fast-Ethernet (100 Mbit/s) Numera o le Vaega: 943958211 Ituaiga o le uafu ma le aofa'i: 8 x 10/100BASE-TX, TP-cable, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity, 2 x 100BASE-FX, MM-cable, SC s...

    • Suiga Pulea Hirschmann GRS103-6TX/4C-2HV-2A

      Suiga Pulea Hirschmann GRS103-6TX/4C-2HV-2A

      Aso Fa'apisinisi Fa'amatalaga o le oloa Igoa: GRS103-6TX/4C-2HV-2A Lomiga o le Polokalama Fa'akomepiuta: HiOS 09.4.01 Ituaiga o le uafu ma le aofa'i: 26 Uafu i le aofa'i, 4 x FE/GE TX/SFP ma le 6 x FE TX fa'apipi'i ua fa'apipi'iina; e ala i Media Modules 16 x FE Isi Fa'aoga Sapalai eletise/feso'ota'iga fa'ailoilo: 2 x IEC plug / 1 x poloka fa'apipi'i, 2-pin, tusi lesona po'o le otometi e mafai ona sui (max. 1 A, 24 V DC bzw. 24 V AC) Pulega Fa'alotoifale ma le Suia o Masini...

    • HIRSCHCHMANN RSPE35-24044O7T99-SCCZ999HHME2AXX.X.XX Fa'atulagaina Fa'aleleia o le Malosiaga o le Suiga o le Alalaupapa

      HIRSCHCHMANN RSPE35-24044O7T99-SCCZ999HHME2AXX....

      Faatomuaga O ki RSPE laiti ma matuā malosi e aofia ai se masini faavae e valu ona uafu ua milo faatasi ma uafu e fa e lagolagoina le Fast Ethernet po o le Gigabit Ethernet. O le masini faavae - e mafai ona maua faatasi ma le HSR (High-Availability Seamless Redundancy) ma le PRP (Parallel Redundancy Protocol) uninterruptible redundancy protocols, faatasi ai ma le taimi sa'o e tusa ai ma le IEEE ...

    • Suiga Ethernet Fa'apisinisi Pulea e Hirschmann MACH102-8TP

      Hirschmann MACH102-8TP Pulea Alamanuia Eteru...

      Fa'amatalaga Fa'amatalaga o le oloa Fa'amatalaga: 26 port Fast Ethernet/Gigabit Ethernet Industrial Workgroup Switch (fa'aleleia ua fa'apipi'iina: 2 x GE, 8 x FE; e ala i Media Modules 16 x FE), pulea, Software Layer 2 Professional, Store-and-Forward-Switching, fanless Design Vaega Numera: 943969001 Avanoa: Aso Mulimuli o le Poloaiga: Tesema 31, 2023 Ituaiga ma le aofa'i o le uafu: E o'o atu i le 26 uafu Ethernet, e o'o atu i le 16 uafu Fast-Ethernet e ala i media modul...