• ulu_fanua_01

MOXA EDS-P506E-4PoE-2GTXSFP-T Gigabit POE+ Puleaina Alamanuia Ethernet Suiga

Fa'amatalaga Puupuu:

O le EDS-P506E Fa'asologa e aofia ai Gigabit pulea PoE + Ethernet ki e sau masani ma 4 10 / 100BaseT (X), 802.3af (PoE), ma 802.3at (PoE +) -tausi Ethernet uafu, ma 2 combo Gigabit Ethernet uafu. O le EDS-P506E Series e maua ai le 30 watts o le mana i le PoE + port i le tulaga masani ma mafai ai ona maua le malosi maualuga e oʻo atu i le 4-paiga 60 W mo fale gaosi oloa mamafa-tiute PoE masini, e pei o le tau-proof IP mataʻituina mea pueata ma wipers / faʻavevela, tulaga maualuga le faʻaogaina o fesoʻotaʻiga, ma telefoni IP gaoa.

O le EDS-P506E Series e sili ona faʻaogaina, ma o le SFP fiber ports e mafai ona tuʻuina atu faʻamatalaga e oʻo atu i le 120 kilomita mai le masini i le nofoaga autu e pulea ma le maualuga o le puipuiga o le EMI. O le Ethernet switches e lagolagoina le tele o galuega tau pulega, e aofia ai le STP / RSTP, Turbo Ring, Turbo Chain, PoE power management, PoE device auto-checking, PoE power scheduling, PoE diagnostic, IGMP, VLAN, QoS, RMON, bandwidth management, and port mirroring. O le EDS-P506E Fa'asologa ua mamanuina fa'apitoa mo fa'aoga faigata i fafo ma le puipuiga o le si'itia 4 kV e fa'amautinoa ai le fa'atuatuaina le fa'alavelaveina o faiga PoE.


Fa'amatalaga Oloa

Faailoga o oloa

Vaega ma Faamanuiaga

E 4 PoE+ ua fausia i totonu e lagolago atu i le 60 W galuega faatino i le uafu.

Smart PoE galue mo le suʻesuʻeina o masini eletise mamao ma le toe faʻaleleia

2 Gigabit combo ports mo fesoʻotaʻiga maualuga-bandwidth

Lagolago le MXstudio mo le faigofie, faʻaalia le faʻatautaia o fesoʻotaʻiga pisinisi

Fa'amatalaga

Feso'ota'iga Ethernet

Taulaga Combo (10/100/1000BaseT(X) poʻo le100/1000BaseSFP+) 2Full/Half duplex modeAuto MDI/MDI-Xconnection

Saosaoa feutanaiga ta'avale

PoE Taulaga (10/100BaseT(X), RJ45 so'oga) 4Full/Half duplex modeAuto MDI/MDI-X so'oga

Saosaoa feutanaiga ta'avale

Tulaga IEEE 802.1D-2004 mo Spanning Tree ProtocolIEEE 802.1p mo Vasega o Au'aunagaIEEE 802.1Q mo VLAN Tagging

IEEE 802.1s mo le Tele Spanning Tree Protocol

IEEE 802.1wmo le Fa'akomepiuta La'au Fa'aola vave

IEEE 802.1X mo le faʻamaoni

IEEE802.3mo le 10BaseT

IEEE 802.3ab mo 1000BaseT(X)

IEEE 802.3ad mo Port Trunkwith LACP

IEEE 802.3u mo 100BaseT(X) ma 100BaseFX

IEEE 802.3x mo le pulea o le tafe

IEEE 802.3z mo 1000BaseSX/LX/LHX/ZX

Parameter Malosi

Voltage Ulufale 12/24/48 VDC, Fa'aulu fa'alua
Galulue Malolo 12 i le 57 VDC (> 50 VDC mo PoE+ galuega faatino fautuaina)
Ulufale i le taimi nei 4.08 A@48 VDC
Max. PoE PowerOutput i le Taulaga 60W
So'oga 2 poloka fa'amau fa'afeso'ota'i 2 e mafai ona aveese
Fa'aaogāina Malosi (Max.) Max. 18.96 W uta atoa e aunoa ma le taumafaina o PDs
Aofa'i PoE Power Budget Max. 180W mo le aofa'i o PD's taumafaina @ 48 VDC inputMax. 150W mo le aofa'i o PD's taumafaina @ 24 VDC inputMax. 62 W mo le aofa'i o le fa'aaogaina o le PD @12 VDC fa'aoga
Ova le uta Puipuia o iai nei Lagolagoina
Puipuiga o le Polarity Reverse Lagolagoina

Uiga Faaletino

Fale Uamea
Fa'ailoga IP IP40
Fua 49.1 x135x116 mm (1.93 x 5.31 x 4.57 ini)
mamafa 910g(2.00 lb)
Fa'apipi'i fa'apipi'i DIN-rail, Fa'amau i luga o le puipui (fa'atasi ai ma pusa fa'apitoa)

Tapulaa o le Siosiomaga

Galulue Vevela EDS-P506E-4PoE-2GTXSFP: -10 i le 60°C (14 i le 140°F)EDS-P506E-4PoE-2GTXSFP-T: -40 i le 75°C (-40 i le 167°F)
Teuga vevela (aofia ai le afifi) -40 i le 85°C (-40 i le 185°F)
Ambient Susū Faatatau 5 i le 95% (e le fa'afefe)

MOXA EDS-P506E-4PoE-2GTXSFP-T Fa'ata'ita'iga Avanoa

Fa'ata'ita'iga 1 MOXA EDS-P506E-4PoE-2GTXSFP-T
Fa'ata'ita'iga 2 MOXA EDS-P506E-4PoE-2GTXSFP

  • Muamua:
  • Sosoo ai:

  • Tusi lau savali iinei ma lafo mai ia i matou

    oloa fa'atatau

    • MOXA EDS-208-M-SC Le Faʻatonuina Alamanuia Ethernet Suiga

      MOXA EDS-208-M-SC Le Faʻatonuina Alamanuia Ethernet...

      Vaega ma Faamanuiaga 10/100BaseT(X) (RJ45 connector), 100BaseFX (multi-mode, SC/ST connectors) IEEE802.3/802.3u/802.3x lagolago Faasalalauga puipuiga o afa DIN-rail mounting gafatia -10 i le 60°C fa'aogaina o le vevela Fa'amatalaga2 Fa'amatalaga2 Etherface Interface Fa'amatalaga2. mo10BaseTIEEE 802.3u mo 100BaseT(X) ma le 100Ba...

    • MOXA NPort 5450 Alamanuia General Serial Device Server

      MOXA NPort 5450 Alamanuia Lautele Fa'asologa Fa'asologa...

      Fa'aaliga ma Fa'amanuiaga Fa'aoga-tagata LCD panel mo le fa'apipi'iina faigofie Fa'amuta fa'agata ma toso maualuga/maualalo fa'asagaga Socket modes: TCP server, TCP client, UDP Configure by Telnet, web browser, or Windows utility SNMP MIB-II for network management 2 kV isolation protection for NPort 5430I/5450I/5450I/5450I-5450I/5450I-T5450I-T5450I-T5450I-T5450I-T5450I-T5450I-5450I-5450I-5450I-5450I-5450I-5450I-5450I-T5450I...

    • MOXA EDS-510A-1GT2SFP Pulea Alamanuia Ethernet Suiga

      MOXA EDS-510A-1GT2SFP Pulea Alamanuia Ethern...

      Fa'aaliga ma Fa'amanuiaga 2 Gigabit Ethernet ports mo redundant mama ma 1 Gigabit Ethernet port mo uplink solutionTurbo Ring and Turbo Chain (taimi toe fa'aleleia <20 ms @ 250 switches), RSTP/STP, ma MSTP mo feso'ota'iga redundancy TACACS +, SNMPv3, IEEE 802.1X feso'otaiga i luga ole upega tafaʻilagi, SLI suʻesuʻe e faʻaleleia atili ai le upega tafaʻilagi a le CLI, CLI 802.1X, fesoʻotaʻiga fesoʻotaiga i le HTTP Telnet/fa'amafanafanaga fa'asologa, fa'aoga Windows, ma ABC-01 ...

    • MOXA EDS-2010-ML-2GTXSFP 8+2G-taulaga Gigabit Le pulea Ethernet Suiga

      MOXA EDS-2010-ML-2GTXSFP 8+2G-taulaga Gigabit Unma...

      Folasaga O le EDS-2010-ML fa'asologa o feso'ota'iga Ethernet fa'apisinisi e valu 10 / 100M 'apamemea ports ma lua 10 / 100 / 1000BaseT (X) po'o 100 / 1000BaseSFP pusa tu'ufa'atasi, lea e lelei mo talosaga e mana'omia ai feso'ota'iga fa'amaumauga maualuga-bandwidth. E le gata i lea, ina ia tuʻuina atu le faʻaogaina sili atu mo le faʻaaogaina ma talosaga mai pisinisi eseese, o le EDS-2010-ML Series e mafai ai foi e tagata faʻaoga ona mafai pe faʻamalo le Tulaga Auaunaga ...

    • MOXA NPort 6450 Secure Terminal Server

      MOXA NPort 6450 Secure Terminal Server

      Features and Benefits LCD panel for easy IP address configuration (standard temp. models) Secure operation modes for Real COM, TCP Server, TCP Client, Pair Connection, Terminal, and Reverse Terminal Nonstandard baudrates lagolagoina ma le saʻo maualuga Port buffers mo le teuina o faʻamaumauga faʻamaumauga pe a le Ethernet e tuimotu Lagolagoina le telefoni feaveaʻi o le IPv6 Ethernet (STP/RSTP)

    • MOXA IMC-21A-S-SC Alamanuia Fa'asalalauga Fa'aliliu

      MOXA IMC-21A-S-SC Alamanuia Fa'asalalauga Fa'aliliu

      Vaega ma Faamanuiaga Tele-mode poʻo le tasi-mode, faʻatasi ai ma le SC poʻo le ST fiber connector Link Fault Pass-Through (LFPT) -40 i le 75°C faʻaogaina o le vevela (-T models) DIP sui e filifili FDX/HDX/10/100/Auto/Force Specifications Faʻamatalaga Faʻamatalaga Ethernet Interface 10/100BaseT(JFX50) Ethernet Interface 10/100BaseT(X4) Taulaga (tele-mode SC feso'ota'iga...