• head_banner_01

MOXA IKS-6728A-4GTXSFP-HV-HV-T 24+4G-port Gigabit Modular Managed PoE Industrial Ethernet Switch

Fa'amatalaga Pupuu:

O le IKS-6728A Series ua mamanuina e faʻafetaui ai manaʻoga o faʻaoga taua mo pisinisi ma alamanuia. O le IKS-6728A ma le IKS-6728A-8PoE e oʻo atu i le 24 10/100BaseT(X), poʻo le PoE/PoE+, ma le 4 combo Gigabit Ethernet ports. O le IKS-6728A-8PoE Ethernet switches e tuʻuina atu le 30 watts o le malosiaga i le PoE+ port i le tulaga masani, ma e lagolagoina foʻi le malosi maualuga e oʻo atu i le 36 watts mo masini PoE faʻapisinisi mamafa, e pei o meapueata mataʻituina IP e teteʻe i le tau ma wipers/heaters, nofoaga e maua ai uaealesi maualuga le faʻatinoga, ma telefoni IP malosi.

E lagolagoina e kisi Ethernet IKS-6728A-8PoE ituaiga e lua o puna o le eletise e ulufale mai ai: 48 VDC mo uafu PoE+ ma le eletise o le polokalama, ma le 110/220 VAC mo le eletise o le polokalama. E lagolagoina fo'i e nei kisi Ethernet le tele o galuega tau pulega, e aofia ai le STP/RSTP, Turbo Ring, Turbo Chain, pulega o le eletise PoE, siakiina otometi o masini PoE, fa'atulagaina o le eletise PoE, fa'ama'i PoE, IGMP, VLAN, QoS, RMON, pulega o le bandwidth, ma le fa'ata'ita'iina o uafu. O le IKS-6728A-8PoE ua mamanuina fa'apitoa mo fa'aoga faigata i fafo ma le puipuiga o le 3kV surge e fa'amautinoa ai le fa'atuatuaina e le motusia o polokalama PoE.


Fa'amatalaga o le oloa

Fa'ailoga o Oloa

Vaega ma Fa'amanuiaga

8 uafu PoE+ ua fausia i totonu e ogatasi ma le IEEE 802.3af/at (IKS-6728A-8PoE)

E oo atu i le 36 W le gaosiga i le uafu PoE+ ta'itasi (IKS-6728A-8PoE)

Mama Turbo ma le Filifili Turbo (taimi e toe fa'aleleia ai)(< 20 ms @ 250 switches) , ma le STP/RSTP/MSTP mo le toe fa'aaogaina o feso'ota'iga

Puipuiga mai le osooso o le 1 kV LAN mo siosiomaga ogaoga i fafo

Su'esu'ega PoE mo le su'esu'ega o le faiga o masini fa'aeletise

4 Gigabit combo ports mo feso'ota'iga maualuga-bandwidth

-40 i le 75°C le vevela o le fa'agaioiga i le 720 W le uta atoa

Lagolagoina le MXstudio mo le faigofie ma le vaaia o le pulega o fesoʻotaʻiga tau alamanuia

E fa'amautinoa e le V-ON™ le toe fa'aleleia o fa'amaumauga multicast ma feso'ota'iga vitio i le tulaga millisecond

Fa'aoga o le Ulufale/Fa'aulufale

Auala Fesoota'i Fa'ailoilo 1 le relay output ma le gafatia e feaveaʻi ai le eletise e 1 A @ 24 VDC

Feso'ota'iga Ethernet

10/100BaseT(X) Ports (feso'ota'iga RJ45) 8
Uafu Fa'atasi (10/100/1000BaseT(X) po'o le 100/1000BaseSFp) 4
Module 2 avanoa fa'apipi'i mo so'o se 8-port po'o le 6-port Interface Modules ma le 10/100BaseT(X), 100BaseFX (SC/ST connector), 100Base PoE/PoE+, po'o le 100Base SFP2
Tulaga Faatonuina IEEE 802.1D-2004 mo le Spanning Tree Protoco

lIEEE 802.1p mo le Vasega o AuaunagaIEEE 802.1Q mo le Fa'ailogaina o le VLAN

IEEE 802.1s mo le Multiple Spanning Tree Protocol

IEEE 802.1w mo le Protocol o le Laau Vave e Fa'asalalauina

IEEE 802.1X mo le fa'amaoniga

IEEE802.3for10BaseT

IEEE 802.3ab mo le 1000BaseT(X)

IEEE 802.3ad mo le Port Trunk faatasi ai ma le LACP

IEEE 802.3u mo le 100BaseT(X) ma le 100BaseFX

IEEE 802.3x mo le puleaina o le tafe

IEEE 802.3z mo le 1000BaseSX/LX/LHX/ZX

Fa'asologa o le Malosiaga

Voltage Ulufale IKS-6728A-4GTXSFP-24-T: 24 VDCIKS-6728A-4GTXSFP-24-24-T: 24 VDC (fa'aulufalega fa'alua e le toe fa'aopoopoina) IKS-6728A-4GTXSFP-48-T: 48 VDC
IKS-6728A-4GTXSFP-48-48-T: 48 VDC (fa'aulufalega fa'alua e le toe fa'aopoopoina) IKS-6728A-4GTXSFP-HV-T: 110/220 VAC
IKS-6728A-4GTXSFP-HV-HV-T: 110/220 VAC (fa'aulufalega fa'alua e le toe fa'aaogaina) IKS-6728A-8PoE-4GTXSFP-48-T: 48 VDC
IKS-6728A-8PoE-4GTXSFP-48-48-T: 48 VDC (fa'aulufalega fa'alua e le toe fa'aopoopoina) IKS-6728A-8PoE-4GTXSFP-HV-T: 110/220 VAC
IKS-6728A-8PoE-4GTXSFP-HV-HV-T: 110/220 VAC (fa'aulufalega fa'alua e le toe fa'aopoopoina)
Voltage Fa'agaoioia IKS-6728A-4GTXSFP-HV-T: 85 i le 264 VAC IKS-6728A-4GTXSFP-HV-HV-T: 85 i le 264VAC IKS-6728A-4GTXSFP-24-T: 18 i le 36 VDC IKS-6728A-4GTXSFP-24-24-T: 18 i le 36 VDC IKS-6728A-4GTXSFP-48-T: 36 i le 72 VDC IKS-6728A-4GTXSFP-48-48-T: 36 i le 72 VDC IKS-6728A-8PoE-4GTXSFP-48-48-T: 36 i le 72 VDC IKS-6728A-8PoE-4GTXSFP-HV-T: 85 i le 264 VAC IKS-6728A-8PoE-4GTXSFP-HV-HV-T: 85 i le 264VAC
Puipuiga o le Taimi Nei e Soona Tele Lagolagoina
Puipuiga o le Polarity Fa'afeagai Lagolagoina
Taimi e Ulufale Mai ai IKS-6728A-4GTXSFP-24-T/4GTXSFP-24-24-T: 0.36 A@24 VDCIKS-6728A-4GTXSFP-48-T/4GTXSFP-48-48-T: 0.19A@48 VDC
IKS-6728A-8PoE-4GTXSFP-48-T/8PoE-4GTXSFP-48-48-T: 0.53 A@48 VDC
IKS-6728A-4GTXSFP-HV-T/4GTXSFP-HV-HV-T: 0.28/0.14A@110/220 VAC
IKS-6728A-8PoE-4GTXSFP-HV-T/8PoE-4GTXSFP-HV-HV-T: 0.33/0.24 A@110/220 VAC

Uiga Faaletino

Fa'atulagaga IP IP30
Fua 440x44x280 mm (17.32x1.37x11.02 inisi)
Mamafa 4100g (9.05 pauna)
Fa'apipi'iina Fa'apipi'iina o le fata

Tapula'a Fa'ale-Siosiomaga

Vevela o le Fa'agaioiga -40 i le 75°C (-40 i le 167°F)
Vevela o le Teuina (ua aofia ai le afifi) -40 i le 85°C (-40 i le 185°F)
Susū Fa'atatau i le Siosiomaga 5 i le 95% (e le fa'aputuina)

MOXA IKS-6728A-4GTXSFP-HV-HV-T Fa'ata'ita'iga o lo'o avanoa

Fa'ata'ita'iga 1 MOXA IKS-6728A-4GTXSFP-24-24-T
Fa'ata'ita'iga 2 MOXA IKS-6728A-4GTXSFP-24-T
Fa'ata'ita'iga 3 MOXA IKS-6728A-4GTXSFP-48-48-T
Fa'ata'ita'iga 4 MOXA IKS-6728A-4GTXSFP-48-T
Fa'ata'ita'iga 5 MOXA IKS-6728A-4GTXSFP-HV-HV-T
Fa'ata'ita'iga 6 MOXA IKS-6728A-4GTXSFP-HV-T
Fa'ata'ita'iga 7 MOXA IKS-6728A-8PoE-4GTXSFP-48-48-T
Fa'ata'ita'iga 8 MOXA IKS-6728A-8PoE-4GTXSFP-48-T
Fa'ata'ita'iga 9 MOXA IKS-6728A-8PoE-4GTXSFP-HV-HV-T
Fa'ata'ita'iga 10 MOXA IKS-6728A-8PoE-4GTXSFP-HV-T

  • Muamua:
  • Sosoo ai:

  • Tusi lau savali iinei ma lafo mai ia i matou

    Oloa e feso'ota'i

    • MOXA IMC-101-M-SC Fa'aliliu Ala o Faasalalauga Ethernet-i-Fiber

      MOXA IMC-101-M-SC Ethernet-i-Fiber Media Conve ...

      Vaega ma Fa'amanuiaga 10/100BaseT(X) feutana'iga otometi ma le auto-MDI/MDI-X Link Fault Pass-Through (LFPT) Le lava o le eletise, fa'ailo o le motusia o le uafu e ala i le relay output Fa'aulufalega eletise fa'aopoopo -40 i le 75°C le vevela o le fa'agaioiga (-T models) Fuafuaina mo nofoaga matautia (Vasega 1 Div. 2/Zone 2, IECEx) Fa'amatalaga Ethernet Interface ...

    • MOXA SFP-1FESLC-T 1-port Fast Ethernet SFP Module

      MOXA SFP-1FESLC-T 1-port Fast Ethernet SFP Module

      Fa'atomuaga O vaega laiti o le Moxa's form-factor pluggable transceiver (SFP) Ethernet fiber modules mo le Fast Ethernet e maua ai le ufiufi i le tele o mamao o fesoota'iga. O vaega o le SFP-1FE Series 1-port Fast Ethernet SFP e maua o ni mea fa'aopoopo e filifili mo le tele o suiga o le Moxa Ethernet. Vaega o le SFP ma le 1 100Base multi-mode, LC connector mo le 2/4 km transmission, -40 i le 85°C operating temperature. ...

    • MOXA ICF-1180I-M-ST Fa'aliliuga Fa'apisinisi PROFIBUS-i-alava

      MOXA ICF-1180I-M-ST Fa'atekonolosi PROFIBUS-i-fibe...

      Vaega ma Fa'amanuiaga Galuega fa'ata'ita'i uaea-fiber e fa'amaonia ai feso'ota'iga a le fiber O le iloa otometi o le baudrate ma le saoasaoa o fa'amaumauga e o'o atu i le 12 Mbps PROFIBUS fail-safe e puipuia ai datagrams ua fa'aleagaina i vaega o lo'o galue Fa'aaliga fa'afeagai a le fiber Lapata'iga ma fa'ailoilo e ala i le relay output Puipuiga o le vavae'eseina o le galvanic 2 kV eletise e lua mo le toe fa'aaogaina (Puipuiga o le malosiaga fa'afeagai) Fa'alauteleina le mamao o le fesiitaiga a le PROFIBUS e o'o atu i le 45 km ...

    • Suiga Ethernet Pulea MOXA EDS-G508E

      Suiga Ethernet Pulea MOXA EDS-G508E

      Faatomuaga O ki EDS-G508E ua fa'apipi'iina i le 8 Gigabit Ethernet ports, ma avea ai ma mea lelei mo le fa'aleleia atili o se feso'ota'iga ua iai nei i le saoasaoa Gigabit po'o le fausiaina o se Gigabit backbone fou atoa. O le Gigabit transmission e fa'ateleina ai le bandwidth mo le fa'atinoga maualuga ma fa'aliliuina vave le tele o auaunaga triple-play i luga o se feso'ota'iga. O tekinolosi Ethernet fa'aopoopo e pei o le Turbo Ring, Turbo Chain, RSTP/STP, ma le MSTP e fa'ateleina ai le fa'atuatuaina o lau...

    • 'Au'aunaga Fa'amaumau Saogalemu a le MOXA NPort 6250

      'Au'aunaga Fa'amaumau Saogalemu a le MOXA NPort 6250

      Vaega ma Fa'amanuiaga Faiga fa'agaoioiga saogalemu mo le Real COM, TCP Server, TCP Client, Pair Connection, Terminal, ma le Reverse Terminal Lagolagoina baudrates e le masani ai ma le sa'o maualuga NPort 6250: Filifiliga o le auala feso'ota'iga: 10/100BaseT(X) po'o le 100BaseFX Fa'aleleia le fa'atulagaina mamao ma HTTPS ma SSH Port buffers mo le teuina o fa'amatalaga fa'asolosolo pe a le o iai le Ethernet Lagolagoina IPv6 Generic serial commands lagolagoina i le Com...

    • Masini Fa'asologa Lautele Fa'apisinisi MOXA NPort 5230

      Masini Fa'asologa Lautele Fa'apisinisi MOXA NPort 5230

      Vaega ma Fa'amanuiaga Fa'ata'ita'iga la'ititi mo le fa'apipi'iina faigofie Fa'aoga o Socket: TCP server, TCP client, UDP Faigofie ona fa'aoga le Windows utility mo le fa'atulagaina o le tele o masini server ADDC (Automatic Data Direction Control) mo le 2-wire ma le 4-wire RS-485 SNMP MIB-II mo le puleaina o feso'ota'iga Fa'amatalaga Ethernet Interface 10/100BaseT(X) Ports (RJ45 connect...